Broadcom fixed a critical authentication bypass in VMware vCenter on 19 November 2026. CVE-2026-123890 (CVSS 9.8) lets an unauthenticated attacker with network access to vCenter get past authentication (VMSA-2026-0009). It was already a zero-day. Google Threat Intelligence Group and Mandiant report that ARMORY CASTLE, a suspected China-nexus espionage group formerly tracked as UNC5221, exploited it in early September 2026 (GTIG). CISA added it to its Known Exploited Vulnerabilities catalog on 20 November with a 23 November deadline (CISA KEV). Broadcom lists no workaround, so patching is the fix. If your vCenter is not on a build in the table below, treat it as urgent.
Fixed vCenter builds
| Product | Affected | Update to (or later) |
|---|---|---|
| vCenter (VCF / vSphere Foundation 9.1) | 9.1.x | 9.1.1.0200 |
| vCenter (VCF / vSphere Foundation 9.0) | 9.0.x | 9.0.2.0200 |
| vCenter Server 8.0 | 8.0 | 8.0 U3m |
| vCenter Server 7.0 | 7.0 | Contact Broadcom Support (extended support contract) |
| VMware Cloud Foundation 5.x | 5.x | 5.2.5 (see KB88287) |
| Telco Cloud Platform / Infrastructure | see advisory | KB463116 |
Source: VMSA-2026-0009, updated 20 November. The same advisory fixes four lower-severity bugs: three in SDDC Manager (CVE-2026-123891, CVE-2026-123892 and CVE-2026-123893, CVSS 6.7 to 8.1) and one in VMware Tools for Windows (CVE-2026-123894, CVSS 6.7), fixed in Tools 13.1.5.0 and 12.5.5. ESXi is not listed as an affected product, but in the attack described below the intruders reached ESXi hosts through vCenter.
vCenter 7.0 has no public fixed build in the advisory. In our reading, a team on 7.0 without an extended support contract has two realistic options: move to 8.0 U3m, or keep vCenter strictly isolated on a management network until it can move. That is our inference, not Broadcom guidance.
How ARMORY CASTLE used it
GTIG describes a single intrusion that started with a different zero-day, CVE-2026-102764 in BeyondTrust Remote Support, which BeyondTrust patched in BT26-05. From there:
- The group moved to internal Linux appliances that had no EDR, planted the SLIMSAVAGE and CAGEMATCH webshells, and made
/bin/envSUID withgdbto get root. - It scanned for VMware ports 9080, 5480 and 2012. Port 2012 is the vCenter SSO control interface that the exploit uses.
- A Go tool named BONESAW exploited CVE-2026-123890 to get a session as
[email protected]. It created an SSO admin account, copied the directory database (data.mdb) and extracted the token signing key. GTIG says BONESAW works against vCenter Server 7.x and 8.x. - A second tool, SAWSNAKE, used that key for Golden SAML: forging tokens, bypassing MFA and impersonating any user.
- The group enabled SSH on vCenter through the appliance management API (
PUT /rest/appliance/access/ssh), took the vCenter master key and PostgreSQL credentials, then switched SSH off again. - On ESXi it logged in as
vpxuserand root, added an SSH key to root'sauthorized_keys, and pulled the Active Directory database (NTDS) and registry hives straight out of guest VM disks. - For persistence it used the BEARBONES SSH backdoor and LAZYBONES, a Slack-controlled backdoor installed as
/usr/bin/vmtoolscs.
The lesson for smaller teams is the last two steps. Once vCenter falls, a domain controller running as a VM can be read from disk without touching Windows at all, so endpoint tools inside the VM never see it.
What to look for
GTIG published these indicators, among others:
/tmp/123 /tmp/sss /tmp/dbr /tmp/123.key /tmp/gdb_file
/usr/bin/vmtoolscs (LAZYBONES, systemd service)
ActiveSer.jsp u.jsp (webshells)
SSH banner: SSH-2.0-pulsesecure_23345
/tmp/dbr -R -p 53 /tmp/dbr -R -p 33992
PUT /rest/appliance/access/ssh
New local accounts named [email protected]
On vCenter, check for SSO administrator accounts nobody created and for SSH being switched on and off. On ESXi, check root's authorized_keys and look for hidden directories such as .a on VMFS volumes. GTIG's post also includes YARA rules and network indicators.
Checklist
- Find every vCenter you run, including the ones inside VCF, lab clusters and old 7.0 installs, and note the build.
- Patch to the fixed build for your line. On 7.0, open a case with Broadcom or plan the move to 8.0 U3m now.
- Restrict network access to vCenter. Only admin workstations or a jump host should reach its management interfaces, including port 2012. vCenter should never be reachable from the internet.
- Patch whatever leads to vCenter. In this case the way in was a remote support appliance. Check your BeyondTrust, VPN and other edge devices too.
- Hunt for the indicators above and review vCenter SSO accounts, SSH enablement and ESXi
authorized_keysfrom September onward. - If you find signs of compromise, assume the signing key is gone. Patching does not invalidate a stolen key. Our view is that you should rebuild vCenter or replace its STS signing certificate following Broadcom guidance, reset
[email protected]and ESXi root passwords, and reset Active Directory credentials if a domain controller VM was on those hosts. That is our inference from GTIG's findings, not vendor guidance. - Consider egress filtering on the appliance. Mandiant recommends its VCSA Hardening & Logging Tool, which enforces iptables rules and remote syslog. Mandiant itself advises testing and change control before you use it in production.
This group has a history with edge devices. Our articles on the Ivanti Connect Secure chain and rotating secrets after NetScaler zero-days cover the same pattern: patch, then assume credentials were taken.
Configuration-management servers are a target too: Puppet Enterprise CVE-2026-115731, an unauthenticated report-upload flaw now in CISA's KEV catalog.
Frequently asked questions
Has Broadcom confirmed exploitation?
The advisory does not mention exploitation. Mandiant reported the bug to Broadcom, GTIG has published the attack details, and CISA lists it as known exploited.
Our vCenter is not on the internet. Are we safe?
Not necessarily. In the case GTIG describes, the attackers got inside through another appliance first and reached vCenter from the internal network. Patch anyway, and limit which internal systems can reach vCenter.
Does Enhanced Linked Mode matter?
No. BleepingComputer reports that, according to Broadcom, vCenter is affected whether or not Enhanced Linked Mode is enabled.
Do we need to patch ESXi?
ESXi is not listed in VMSA-2026-0009. The fix is for vCenter, SDDC Manager and VMware Tools for Windows. Still check ESXi hosts for the signs above, because a compromised vCenter gives access to them.
Sources: Broadcom VMSA-2026-0009, Google Threat Intelligence Group and Mandiant, 20 November 2026, CISA KEV catalog (via the KEV data feed), NVD and BleepingComputer.